- LicensedTexas Master Plumber 40980
- On call 24/7Licensed plumbers for emergencies
- Brazos ValleyCollege Station, Bryan and nearby
A fire pit, an outdoor fireplace or a gas lamp is a gas appliance sitting out in the yard. The plumbing is the line that feeds it, the valve that shuts it off, and the test that proves the whole thing holds.
Nearly every fire feature problem we get called to traces back to a decision somebody made before the trench closed. Plan it with the rest of the outdoor living work.

WHAT WE DO, AND WHAT THE BUILDER DOES
Outdoor fire features usually involve two trades, and the line between them is worth stating before anybody starts.
Our Side of It
We size the line for the load and run it. We set the shutoff valve, make the connection to the appliance and pressure test the system. We handle the permit and the inspection.
The Other Side of It
The surround, the burner pan, the media and the finish are set by whoever builds the feature. We work to the manufacturer’s instructions for the burner you chose.
Bring Us the Model Number Early
The instructions that ship with the appliance govern the installation. Clearances, the connection, the valve arrangement and the BTU rating all come off that document, and we would rather read it before we size anything.
THE BURNER IS A LISTED APPLIANCE, AND THAT MATTERS
Outdoor decorative gas appliances are covered by a harmonized standard, CSA 2.41 and ANSI Z21.97, with certification carried out by CSA or UL.
An inspector looks for that listing and for the manufacturer’s instructions. A burner built out of parts, carrying no listing, becomes a problem at inspection. Better to know that before you order the masonry.
What our customers say
Published exactly as written, straight from Google.
Found late Friday evening that I did not have hot water, and it was the weekend... YIKES!! Contacted 4L Contracting LLC; they came out within a couple of hours and had me working in a short time. Lee went above and beyond, letting me know about other problems identified in my attic, a problem with my chimney, and a heating vent installation problem. After he left, I found a water leak in the laundry room ceiling. He turned around and came back to my house. He found the air conditioning drain pipe was backed up. He blew it out the drain pipe, preventing a big disaster. So appreciate his thoroughness and helping me on a Friday after-hours house call. He definitely went above and beyond.
I had a great experience working with 4L Contracting LLC. They were awesome to work with, they were professional, responsive, and clearly knew what they were doing. We had a massive leak that needed immediate attention, and they showed up quickly and handled it efficiently. They not only fixed the issue fast but also made sure everything was done right. I would absolutely recommend them to anyone needing reliable, high quality work!
Used 4L Contracting the first time a couple years ago and since then they have replaced a water heater, reset toilets, replaced water lines, and located and fixed a leak under the house! They have been amazing to work with over the years, I cannot recommend these guys enough!
Water Softener installation Completed! Just wanted to give a shout out to Kurt and Lane on their outstanding customer service today. I hired 4L Contracting LLC to install a water softener in our home. After finding out the water softener I had purchased was missing parts, the job was rescheduled for Monday. I was able to return the water softener and get a replacement fairly quick. So I sent a text to Kurt, letting him know I had done so. He informed me they were nearby and could do the job in about 30 minutes if I could meet them back at my home. I hurried home and in about 2 hours the job was completed. Tonight my wife and I shall enjoy a soft water shower!
My husband and I had a broken pipe in the foundation and it was leaking pretty bad into our hallway, and 4L Contracting came that day we called, assessed the issue, and was back the next day and completely fixed the problem. They were so nice and helpful! I cannot tell you how pleased we were with their service. I recommend 4L Contracting!
My wife and I discovered a water leak coming out of our wall. 4L Contracting LLC came out that day and found where the leak was coming from (copper pipe leaking in the slab), they started working immediately and finished the next day.
These plumbers are honest, knowledgeable and reliable! They helped us fix a leak and answered all our questions about other issues in the house. Highly recommend!
Lee and his guys are Great. Their communication on our projects have been superb! Always letting us know when they will be at the job site. Lee is doing 3 projects for our Airbnb's at one time, and his organization of his paperwork is paramount for us.
WHAT IT COSTS AND HOW YOU PAY
Four things move the number. Distance from the meter, the BTU rating of the appliance, what lies under the yard, and whether the existing system can carry the load. We do not publish a price that will not apply to your project. We give you a firm written price once we have seen the site and the appliance specifications.
Price in Writing Before Work Starts
You get a written price covering the scope we recommend and what it includes. No verbal estimates. No extra charges added after the fact. You approve the scope and cost before we start.
Workmanship Warranty
Every installation we perform is backed by a workmanship warranty. If a problem with our work develops within the warranty period, we return and fix it at no charge to you.
Office Hours and Emergency Availability
Office hours Monday to Friday, 7 AM to 5 PM. Licensed plumbers on call 24/7 for plumbing emergencies. Reach us at 979-473-9775.
4L Contracting holds Texas Master Plumber License 40980. You can verify any Texas plumbing license at tsbpe.texas.gov.
Over 50 years of combined experience. 5 star rated service. Serving College Station, Bryan, Brenham and surrounding Brazos Valley counties.
SIZING IS ABOUT THE WHOLE SYSTEM, NOT JUST THE FIRE PIT
A fire feature is a bigger draw than most people expect, and it does not exist on its own.
The Meter Has to Carry Everything at Once
Your furnace, water heater, range, dryer, pool heater and grill are all on the same supply. We add the new load to what is already there rather than looking at the fire pit alone.
Distance Costs You Pressure
A long run to the far end of the yard drops pressure. The pipe size that works at the house may not work at the feature. That is a calculation, not a guess.
Adding It Later Is a Different Job
Extending an existing system means proving the existing system can take it. Sometimes it can. Sometimes the answer is a larger run from the meter, and you want to hear that before the slab for the patio goes down.

GETTING THE LINE ACROSS THE YARD
Underground gas piping runs to its own set of rules, and they are specific enough to be worth reading before you dig anything yourself.
Depth of Cover
Underground piping goes in at least 12 inches below grade. A supply serving one outdoor appliance, a grill or a light, has a lower minimum of 8 inches subject to the code official. It still has to sit where nothing will damage it.
Plastic Stays Underground
Plastic pipe is for outdoors underground only. It is not permitted within or under a building or a slab. Where it comes back above grade, it does so in a premanufactured anodeless riser.
Transitions and Tracer Wire
The joint between metal and plastic uses a transition fitting made for the job. A yellow insulated copper tracer wire runs alongside the plastic, 18 AWG or heavier and rated for direct burial. Access at each end is what lets somebody locate that line later.
Anything Under the Building Is Sleeved
Piping that passes beneath a building runs inside an approved conduit, sealed and vented at its ends. That is not the same as burying pipe in a trench, and it is not a place to economize.
THE SHUTOFF, AND THE EXCEPTION FOR DECORATIVE APPLIANCES
Every gas appliance gets a shutoff valve you can actually reach. The general rule is a valve within 6 feet of the appliance, accessible, and upstream of the connector it serves.
Fireplaces and decorative appliances have their own arrangement in the code, because a valve buried inside a stone surround is no use to anybody. The remote valve has to carry permanent identification and go in the way the manufacturer’s instructions require.
The practical version is simple. You should be able to shut the gas off to that fire pit in the dark without taking the feature apart.
OUTDOOR FIREPLACES, AND WHAT CHANGES
A built fireplace is the same gas problem with a masonry schedule attached to it.
The Stub Goes In Before the Stone
The line has to be in place and protected before anybody builds the surround around it. Afterwards is demolition.
Log Sets and Burners Are Not Interchangeable
An outdoor rated appliance is not the same as an indoor gas log set, and the two carry different instructions. Pick the appliance first.
Clearances Come From the Appliance
How close the feature can sit to a wall, a roof overhang or a fence comes off the listing, not off a rule of thumb.
Not sure where to start?
Talk to a licensed plumber
Describe what your plumbing is doing and we will tell you what it likely is before anyone comes out.
GAS LAMPS AND LANTERNS
A gas lamp is the smallest appliance on this page and the only one designed to run all the time. That changes what matters about it.
Small Per Hour, Constant All Year
Residential lamps generally fall between about 2,200 and 4,900 BTU per hour, depending on the burner. A fire pit is far larger and runs for an evening. A lamp is small and never stops, so ask what a year of it costs before you buy one.
They Have Their Own Listing Standard
Fire pits fall under CSA 2.41 and ANSI Z21.97. Gas lamps have their own, CSA and ANSI Z21.42, for gas fired illuminating appliances. Antique and reproduction fixtures sometimes carry no listing at all, which is worth settling before one goes up.
Post Mounted Is a Riser Question
A lamp on a post is the exact case the burial rules describe. The run goes underground in plastic, comes up in a premanufactured anodeless riser, and carries its tracer wire with it. That is the individual outdoor appliance behind the 8 inch minimum.
Wall Mounted Is a Penetration Question
A lamp on the house means a line through the wall, sealed and supported where it passes. The connector and the valve both have to stay reachable once the fixture is up. A lamp over a door is easy to mount and awkward to service.
A Shutoff You Can Reach in the Dark
Many lamps are simple open flame fixtures with a manual valve and nothing else. There is no thermostat, and often no flame failure device, so that valve is the control. It belongs somewhere you can find without a ladder.
Ignition and Timers Are Not Plumbing
Some lamps offer electronic ignition, a timer or a photocell, so they are not burning through the middle of the day. Those need power, and the electrical side belongs to an electrician. We run and connect the gas.
NOTHING GETS LIT UNTIL IT PASSES A PRESSURE TEST
New gas piping is pressure tested and inspected before any gas goes into it. That applies to a 10 foot extension and to a run across the whole yard.
We do not turn gas on to a system that has not passed. See adding a gas line for how we run that part of the work. See gas line services for repairs and leak work on a system you already have.
PERMITS AND YOUR JURISDICTION
Gas work needs a permit and an inspection. Which code edition applies, and what the local amendments add, varies across the Brazos Valley.
We tell you what your jurisdiction wants before the work starts rather than discovering it at inspection.
PLAN IT WITH THE REST OF THE PROJECT
Fire features rarely arrive alone. If an outdoor kitchen is going in as well, the water, the drain and the gas share one trench and one set of decisions.
On a new build, this belongs in the plan before the slab. See new home plumbing, or barndominium plumbing if the house and the shop are under one roof.
FIRE PIT AND FIREPLACE GAS LINES NEAR YOU
We run gas to outdoor fire features across College Station, Bryan and the towns around them. Pick your town, or check whether we cover your area.
CALL BEFORE THE TRENCH CLOSES
Everything on this page stays straightforward while the ground is open and the stone still sits on a pallet. Call us with the appliance you picked and where you want it, and we will tell you what the run takes.
Office hours Monday to Friday, 7 AM to 5 PM. Licensed plumbers on call 24/7 for plumbing emergencies. Serving College Station, Bryan, Brenham and surrounding Brazos Valley counties.
Call 979-473-9775Request an Estimate OnlineGet a starting price
Not the job you have? See all plumbing services, or call 979-473-9775 and describe what you are seeing.
Have a plumbing question? Contact an expert.